Lonrecon Automated External Defibrillator LR-AED-7000 | Portable AED | Biphasic Output | Easy Operation
LR-AED-7000 is a portable automated external defibrillator with biphasic energy output, automatic rhythm analysis, and guided user prompts for effective emergency cardiac response.
LR-AED-7000 Automated External Defibrillator for Emergency Cardiac Support
Portable AED with automatic heart rhythm analysis, guided prompts, and safety features for public and clinical use
The LR-AED-7000 is an advanced automated external defibrillator designed to provide emergency cardiac support during sudden cardiac arrest (SCA). It automatically detects the patient’s heart rhythm, analyzes it, and determines whether a shock is needed to restore effective cardiac activity. The device then delivers a controlled biphasic energy shock to improve the chance of return of spontaneous circulation (ROSC).
Featuring a simple two-button operation and extensive audio and visual prompts, LR-AED-7000 guides users of all experience levels—lay rescuers and trained responders alike—through the entire defibrillation process. Its intuitive design minimizes hesitation and ensures rapid response when every second counts.
With a three-step defibrillation process, reliable self-tests, and robust internal safety systems, LR-AED-7000 is suitable for installation in public spaces, workplaces, and healthcare environments where quick access to defibrillation can save lives.
General Information
-
Model: LR-AED-7000
-
Product Type: Automated External Defibrillator (AED)
-
Design: Portable, rugged housing for emergency use
-
Intended Users: Suitable for trained responders and lay rescuers
Defibrillation & Analysis
-
Defibrillator Type: Fully automatic external defibrillator
-
Waveform Technology: Biphasic truncated exponential output
-
Energy Sequence: 150 J, 150 J, 200 J (adult)
-
Automatic Rhythm Detection: Built-in ECG analysis determines shock necessity
-
Defibrillation Steps: Three-step automatic defibrillation process
-
Controls: Two buttons (On/Off, Shock) for simple operation
-
Energy Accuracy: ±15% into specified impedance ranges
-
Maximum Output Voltage: Approx. 1200 ± 50 V
-
Lead Lock-out Protection: Prevents unintended shock delivery
-
Guided Prompts: Extensive voice prompts and LED visual indicators
Performance Metrics
-
Analysis Time: Approx. 9 seconds
-
Charge Time:
-
~8 seconds to 150 J
-
~10 seconds to 200 J (with new battery)
-
-
Ready-to-Shock Time:
-
≤ 30 seconds from start of rhythm analysis (new battery)
-
≤ 35 seconds after 6 cumulative shocks
-