LR-SP05 Syringe Pump
Reliable syringe pump for accurate IV medication delivery. Supports common syringe sizes, KVO mode, and safety alarms. Suitable for ICU, NICU, and routine hospital use.
-
Model: LR-SP05
-
Syringe sizes: 10 / 20 / 30 / 50 mL
-
Accuracy: ±3%
-
Infusion rate:
-
10 mL: 0.1–100 mL/h
-
20 mL: 0.1–200 mL/h
-
30 mL: 0.1–300 mL/h
-
50 mL: 0.1–500 mL/h
-
-
KVO rate: 0.1–5 mL/h
-
Occlusion alarm: Low / Medium / High (adjustable)
-
Power supply: AC 100–240V, 50/60Hz
-
Battery: Rechargeable lithium battery
-
Net weight: Approx. 1.7 kg
-
Applications: ICU, NICU, wards, emergency, operating room
LR-SP05 Portable IV Syringe Pump – Accurate Infusion for ICU/NICU
Lonrecon LR-SP05 syringe pump is designed for stable and precise IV medication delivery in hospital wards and high-acuity clinical environments. In many Africa, Middle East, and South America healthcare systems, buyers prioritize reliability, ease of use, and repeat supply rather than overly complex features. LR-SP05 focuses on consistent performance, intuitive operation, and clear alarms for everyday clinical workflows.
As an IV syringe pump, LR-SP05 supports adjustable infusion rate and VTBI settings for controlled drug delivery in ICU, NICU, operating rooms, and emergency departments. After infusion completion, the pump can automatically enter KVO mode to maintain vein patency, aligning with standard hospital procedures. Adjustable occlusion pressure alarms help balance safety and reduce unnecessary alerts during long infusions.
For distributors and hospital procurement teams, LR-SP05 is also a practical syringe infusion pump for bulk sourcing. Lonrecon supports bulk pricing, OEM/ODM private labeling, and export documentation commonly required for regional tenders. Configuration and accessories can be aligned across batches, making repeat orders easier and more consistent.
c
| Parameter (EN) | Specification (EN) |
|---|---|
| Model | LR-AW-EA |
| Power Supply | AC 110/220V, 50/60Hz |
| Power Input | 900 VA |
| Control Mode | Manual / Automatic (Microprocessor Servo Control) |
| Skin Temperature Control Range | 32°C – 38°C |
| Skin Temperature Control Accuracy | ≤ 0.5°C |
| Skin Temperature Sensor Accuracy | ± 0.3°C |
| Mattress Temperature Uniformity | < 2°C |
| Warm-up Time (from 25°C) | < 30 minutes |
| Distance from Heater to Mattress | 80 cm |
| Mattress Size | 67 × 54 cm |
| Observation Light | LED, adjustable brightness |
| Radiant Heat Source | Quartz infrared radiant tube (anti-explosion) |
| Protective Panels | 4 transparent foldable panels with infusion ports |
| Alarm System | Power failure, temperature deviation, sensor failure, skin temp failure, over-temperature |
| Safety Protection | Secondary thermal cut-off protection |
| Communication Interface | RS-232 |
| Net Weight | 40 kg |
| Gross Weight | 60 kg |
| Packing Size | 110 × 81 × 83 cm |